Image Production Quick Quiz 1
Quiz Summary
0 of 19 questions completed
Questions:
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- 9
- 10
- 11
- 12
- 13
- 14
- 15
- 16
- 17
- 18
- 19
Information
You have already completed the quiz before. Hence you can not start it again.
Quiz is loading…
You must sign in or sign up to start the quiz.
You must first complete the following:
Results
Results
0 of 19 questions answered correctly
Your time:
Time has elapsed
You have reached 0 of 0 point(s), (0)
Earned Point(s): 0 of 0, (0)
0 Essay(s) Pending (Possible Point(s): 0)
Categories
- image production 0%
- 1
- 2
- 3
- 4
- 5
- 6
- 7
- 8
- 9
- 10
- 11
- 12
- 13
- 14
- 15
- 16
- 17
- 18
- 19
- Answered
- Review
-
Question 1 of 19
1. Question
Patient motion results in ____________ in the CT image.
1. Ghosting
2. Blurring
3. StreaksCorrectIncorrect -
Question 2 of 19
2. Question
As slice thickness is decreased, which of the following statements is true?
CorrectIncorrect -
Question 3 of 19
3. Question
To reduce the effect of partial volume artifact in a CT image while not increasing the appearance of noise, which of the following could be used?
CorrectIncorrect -
Question 4 of 19
4. Question
A variation in which of the following factors will affect the hardening of the CT x-ray beam?
1. Tissue density
2. kVp
3. Tissue thicknessCorrectIncorrect -
Question 5 of 19
5. Question
The direction in which the streaks from the edge gradient effect emanate in what orientation from the structure being imaged?
CorrectIncorrect -
Question 6 of 19
6. Question
The CT image of the brain exhibiting a cupping artifact will appear brighter…
CorrectIncorrect -
Question 7 of 19
7. Question
Partial volume averaging may result from which of the following?
1. Lack of sharpness of edges
2. Inaccurate CT numbers
3. Ghosting of tissue boundariesCorrectIncorrect -
Question 8 of 19
8. Question
Which of the following best describes a CT artifact?
CorrectIncorrect -
Question 9 of 19
9. Question
The greatest amount of partial volume artifact would be displayed in which of the following?
CorrectIncorrect -
Question 10 of 19
10. Question
When scan time is decreased:
CorrectIncorrect -
Question 11 of 19
11. Question
The appearance of tube arcing on the CT image might result in…
CorrectIncorrect -
Question 12 of 19
12. Question
Beam hardening can produce which of the following?
1. Broad streaks in the image
2. Inaccuracies in the CT number
3. Cupping artifactCorrectIncorrect -
Question 13 of 19
13. Question
Which of the following scan parameters will produce a CT image with the least amount of edge gradient artifacts?
CorrectIncorrect -
Question 14 of 19
14. Question
If the filter at the aperture of the x-ray tube removed even more low energy x-ray photons which of the following would result?
CorrectIncorrect -
Question 15 of 19
15. Question
The cause of the cupping artifact is?
CorrectIncorrect -
Question 16 of 19
16. Question
CT images can be directly scanned in planes other than transverse and can be acquired by orienting the patient’s body part so that it is not perpendicular to the x-ray beam.
CorrectIncorrect -
Question 17 of 19
17. Question
Which of the following will reduce the appearance of noise in the CT image.
1. Use of a wide window width
2. Increase in mAs
3. Increase in slice thicknessCorrectIncorrect -
Question 18 of 19
18. Question
Which of the following will most likely remove a ring artifact?
CorrectIncorrect -
Question 19 of 19
19. Question
An artifact from a faulty detector would appear on a localizer image as…
CorrectIncorrect